Difference between revisions of "Live Burn Training"
From Standard Operating Guidelines
Mfrdmanager (talk | contribs) (→Policy: I. Instructor Assignments:) |
Mfrdmanager (talk | contribs) |
||
Line 34: | Line 34: | ||
*#Monitors interior temperatures and conditions consistently. | *#Monitors interior temperatures and conditions consistently. | ||
*#Immediately stops all activities if necessary to prevent injury or accidents. | *#Immediately stops all activities if necessary to prevent injury or accidents. | ||
+ | * Team Leaders: | ||
+ | *#Provides direct instruction to the students that are assigned to them and maintains a maximum student to instructor ratio of 4:1. | ||
+ | *#Maintains accountability of their assigned students. | ||
+ | *#Maintains communications with Command. | ||
+ | |||
+ | |||
+ | ===Mobile Training Facility- Live Burn Training=== | ||
+ | |||
+ | ===Live Fire Evolution Procedures:=== | ||
+ | * Command: | ||
+ | *#Removes all locks from all units, with no exceptions prior to burn evolutions. | ||
+ | *#Ensures an engine is on site and drafting from the dump tank. | ||
+ | *#Ensures that the attack and back-up lines are deployed. | ||
+ | *#Ensures all positions have radios and an understanding of radio procedures. | ||
+ | *#Ensures accountability procedures are in place. | ||
+ | *#Performs a facility walk-through. | ||
+ | *#Assures proper records and checks off lists are prepared and utilized | ||
+ | * Safety Officer: | ||
+ | *#Assembles/ connects temperature data logger in a ready position | ||
+ | *#Monitors temperatures and assures that they don't exceed: | ||
+ | *#*800 degrees F at the ceiling. | ||
+ | *#*400 degrees F at the "helmet height". | ||
+ | *#Verifies temperatures using a thermal imager. | ||
+ | *#Controls ventilation devices. | ||
+ | *#Ensures all personnel are in full PPE | ||
+ | *#Alternates positions with Ignition Officer on each burn. | ||
+ | *#Verbally reviews Safety Concept prior to beginning the evolution. | ||
+ | *#Ensures all crews participating in training have pre and post vital signs monitored and documented. Ensures that crews undergo rehab per policy or as needed. | ||
+ | * Ignition Officer: | ||
+ | *#Sets up burn using CLASS A Materials- NO EXCEPTIONS. | ||
+ | *#*Maximum of Three pallets in the floor rack. | ||
+ | *#*Maximum of Two half pallets in the ceiling chains. | ||
+ | *#*Straw as necessary. | ||
+ | *#Assures back-up line is staffed and charged between trailers prior to ignition | ||
+ | *#Alternates positions with Safety Officer on each burn | ||
+ | *#After three burns, ensures that the trailer is cooled to 100 degrees F and interior of trailer is cleared of burn debris before beginning next training evolution. | ||
+ | |||
+ | ===Live Fire Forms to be completed pre and post training:=== | ||
+ | * Live Fire Training Worksheet. | ||
+ | *#To be completed prior to and after live fire training. | ||
+ | * Safety Officer Check list, Safety Briefing, and Post Burn and Fire Critique. | ||
+ | *#To be completed prior to and after live fire training. | ||
+ | * Assumption of Risk Form. | ||
+ | *#To be completed prior to live fire training. | ||
+ | * Written Training Plan. | ||
+ | *#To be completed and turned into Assistant Chief Van Camp for approval prior to training. | ||
+ | |||
[[Category:Fire Operations - Special Operations]] | [[Category:Fire Operations - Special Operations]] |
Revision as of 14:30, 8 June 2016
Contents
Section 2 - EMERGENCY OPERATIONS
230.11 Live Burn Training
PURPOSE:
To standardize the live burn operation of the MFRD Training Facility in the safest manner possible while providing a high quality and consistent training experience within the parameters of NFPA 1403
SCOPE:
This policy applies to anyone conducting or participating in live fire training in the MFRD Mobile Fire Training Facility. A minimum of four Florida State Certified Fire Instructors will be present at any and all live fire training activities.
Instructor Assignments:
- Command is responsible for:
- Position will be filled by a State Certified Instructor.
- Overall responsibility for planning and executing live fire evolutions.
- Assigns instructors to fill the following positions:
- Safety Officer – Minimum of State Certified Instructor.
- Safety Line Instructor – Any State Certified FFII.
- Ignition Officer – Minimum of Adjunct Fire Instructor.
- Team Leaders – Minimum of Adjunct Fire Instructor.
- Completes check lists and paperwork.
- Conducts a walk through with any individuals that are participating in the training.
- Monitors time during evolutions.
- Manages accountability.
- Conducts a post evolution critique after every evolution.
- Safety Officer:
- Immediately stops all activities if necessary to prevent injury.
- Maintains a safe environment at all live fire evolutions.
- Prevents unsafe acts and eliminate unsafe conditions.
- Monitors all aspects of the training and be proactive in the inspection, planning and preparation phases.
- Monitors temperatures during live fire evolutions.
- Safety Line Instructor:
- To man the safety line on the exterior of the burn room for safety purposes.
- Ignition Officer:
- Responsible for the ignition and control of the materials (CLASS A ONLY) being burned. No exceptions to fuel- CLASS A ONLY.
- Monitors interior temperatures and conditions consistently.
- Immediately stops all activities if necessary to prevent injury or accidents.
- Team Leaders:
- Provides direct instruction to the students that are assigned to them and maintains a maximum student to instructor ratio of 4:1.
- Maintains accountability of their assigned students.
- Maintains communications with Command.
Mobile Training Facility- Live Burn Training
Live Fire Evolution Procedures:
- Command:
- Removes all locks from all units, with no exceptions prior to burn evolutions.
- Ensures an engine is on site and drafting from the dump tank.
- Ensures that the attack and back-up lines are deployed.
- Ensures all positions have radios and an understanding of radio procedures.
- Ensures accountability procedures are in place.
- Performs a facility walk-through.
- Assures proper records and checks off lists are prepared and utilized
- Safety Officer:
- Assembles/ connects temperature data logger in a ready position
- Monitors temperatures and assures that they don't exceed:
- 800 degrees F at the ceiling.
- 400 degrees F at the "helmet height".
- Verifies temperatures using a thermal imager.
- Controls ventilation devices.
- Ensures all personnel are in full PPE
- Alternates positions with Ignition Officer on each burn.
- Verbally reviews Safety Concept prior to beginning the evolution.
- Ensures all crews participating in training have pre and post vital signs monitored and documented. Ensures that crews undergo rehab per policy or as needed.
- Ignition Officer:
- Sets up burn using CLASS A Materials- NO EXCEPTIONS.
- Maximum of Three pallets in the floor rack.
- Maximum of Two half pallets in the ceiling chains.
- Straw as necessary.
- Assures back-up line is staffed and charged between trailers prior to ignition
- Alternates positions with Safety Officer on each burn
- After three burns, ensures that the trailer is cooled to 100 degrees F and interior of trailer is cleared of burn debris before beginning next training evolution.
- Sets up burn using CLASS A Materials- NO EXCEPTIONS.
Live Fire Forms to be completed pre and post training:
- Live Fire Training Worksheet.
- To be completed prior to and after live fire training.
- Safety Officer Check list, Safety Briefing, and Post Burn and Fire Critique.
- To be completed prior to and after live fire training.
- Assumption of Risk Form.
- To be completed prior to live fire training.
- Written Training Plan.
- To be completed and turned into Assistant Chief Van Camp for approval prior to training.